NAP-550 Electrochemical Nitrogen Dioxide Gas Sensor



Features:

Specifications


Detectable gas:

Nitrogen Dioxide (NO2

Detection range:

0 – 30 ppm

Maximum overload:

100 ppm

Output current:

150 +/- 30 nA/ppm

Reproducibility:

+/- 2%

Output drift in air:

less than 4% /month

Response time (90%):

< 30 seconds

Temp. depend. in air:

<10ppm (0-40°C)

Expected lifetime:

>2 years

Operating conditions


Operating temperature:

-20 +50 degrees C

Humidity range:

15 – 90% RH

Pressure:

0.9 – 1.1 atm

Recommended resistor:

10 ohms

Bias voltage:

Not required

NAP-550Datasheet.pdf

General Description:

The NAP-550 is a new electrochemical gas sensor with 3 electrodes for the detection of Nitrogen Dioxide (NO2) in a variety of gas detection applications. Exhibiting high performance with long- term stability, this compact sensor is suitable for portable or disposable Gas Detection Instruments or Fixed Gas Detection heads alike. The NAP-550 is a version of the popular NT-NO2, designed to be mechanically compatible with the NAP-505 CO sensor when used in applications such as underground Car Park monitoring

Nemoto's porous electrode technology enables accurate gas detection with high sensitivity. The mechanical design of the sensor gives optimum gas diffusion characteristics, and the hermetically sealed enclosure prevents costly electrolyte leakage.