top of page

NE7-CO-H Range - Hydrogen Immune

Special 4-Electrode Industrial Carbon Monoxide (CO) Sensors

NE7-CO-H.png

General Description:

The NE7-CO-H range are two new electrochemical gas sensors with 4 electrodes, for the detection and monitoring of Carbon monoxide (CO). The sensor is particularly suitable for applications where zero sensitivity to Hydrogen is essential, such as Flue Gas Analysers and Anti-smoking breath-testers. The performance of the sensor is designed to conform with EN 50379 in Flue Gas Analysers. These sensors require a special circuit.

​

Nemoto's porous electrode technology enables accurate gas detection with high sensitivity. The mechanical design of the sensor gives optimum gas diffusion characteristics, and the hermetically sealed enclosure prevents costly electrolyte leakage. 2 Options are availablle:

​

NE7-CO-H (0-1000 ppm range)

NE7-CO-H10000 (0-10,000 ppm range)

Specifications

Detectable Gas:  Carbon Monoxide (CO)

NE7-CO-H                   NE7-CO-H10000

Detection range:

Maximum overload:

Output current:

Zero Offset (20°C)

Reproducibility:

Output drift in air:

Response time (90%):

Temp. depend. in air:

Expected lifetime:

Operating temperature:

Humidity range:

Pressure:

Recommended resistor:

Bias voltage:

0 – 1000 ppm

2000 ppm

100 +/- 20 nA/ppm

<+/- 5 ppm equivalent

+/- 1%

< 5% / year

< 35 seconds

-3 to +15ppm (-20 to 50°C)

>2 years

-20 +50 degrees C

15 – 90% RH

0.9 – 1.1 atm

10 ohms

Not required

0 – 10,000 ppm

20,000 ppm

15 +/- 4 nA/ppm

TBA

+/- 2%

< 5% / year

< 40 seconds

-10 to +50ppm(-20 to 50°C)

>2 years

-20 +50 degrees C

15 – 90% RH

0.9 – 1.1 atm

10 ohms

Not required

​

bottom of page