top of page

NCP-180

Catalytic twin-header pellistor flammable Gas Sensor for Industrial Environments

NCP-180 flammable gas sensor

Specifications

Detectable Gas:

Detection range:

Voltage supply:

Current drawn:

Minimum Sensitivity:

Zero Offset (20°C):

Response time (90%):

Accuracy:

Expected lifetime:

Long Term Span Drift:

Long Term Zero Drift:

All Flammable Gases

0 – 100% LEL

2.6V +/- 0.2V

175mA +/- 10 mA

20mV / % CH4

0mV +/-  30mV

< 8 seconds

+/- 1% LEL

> 3 years

<+/- 1% FSD/ month

<+/- 0.5mV / month

Operating Conditions

Operating temperature:

Humidity range:

Pressure:

Temperature Drift (zero):

Linearity:

-20 +60°C

0 – 95% RH

0.9 – 1.1 atm

<+/- 2% LEL

Effectively linear to 0-100% LEL

General Description:

The Nemoto NCP-180 is a catalytic (pellistor) type flammable gas sensor supplied as a matched pair of elements mounted on TO4 size headers and protected by a metal can.  The sensor detects and measures the presence of flammable gases and vapours in air, in the range 0-100% of the Lower Explosive Limit (LEL) of the gas or vapour being measured.

Designed as a sensing platform for use in fixed flammable gas detection systems, the NCP-180 exhibits excellent long term zero and sensitivity stability and a high level of resistance to catalytic poisons. The device is compatible with a wide range of commercially available Gas Detection Systems and remote flammable gas detection heads.

  •        Measures flammability directly

  •        Highly resistant to Catalyst poisons

  •        Resistant to shocks and vibration

  •        Effectively Linear output to 100%LEL

  •        Specific to flammable  gases

  •        Unaffected by Humidity

  •        Very Simple circuitry

  •        Very Low Long term drift
     

bottom of page